Micro Motion H-Series Hygienic Coriolis Meter | DN250-DN350 | 316L Stainless Steel | H400S Sensor with 2400S Transmitter

As a supplier, the Micro Motion H-Series Hygienic Coriolis Meter, consisting of the H400S sensor and 2400S transmitter, offers exceptional measurement accuracy and reliability. Our efficient supply chain ensures timely delivery and ample inventory, while we provide customized services to meet specific needs. Our professional team also offers comprehensive technical support and maintenance services, ensuring a smooth experience for customers and supporting your business success.

  • Free Selection Free Online Product Selection Service

To pick up today

  • Fast Shipping & Competitive pricing

Our courier will deliver to the specified address

  • warranty Min. order: 1 piece & 2-Year Warranty

DHL courier will deliver to the specified address

Payment Methods:

Description

Specification Details
Micro Motion H400S Hygienic Coriolis Meter 4 Inch (DN100), 316L Stainless Steel, 32 RA Finish
Mass flow accuracy (Liquid) Up to ±0.05% of rate
Mass flow repeatability (Liquid) Up to ±0.025% of rate
Volume flow accuracy (Liquid) Up to ±0.05% of rate
Volume flow repeatability (Liquid) Up to ±0.025% of rate
Mass flow accuracy (Gas) Up to ±0.35% of rate
Mass flow repeatability (Gas) Up to ±0.175% of rate
Density accuracy (Liquid) Up to ±0.0005 g/cm³ (±0.5 kg/m³)
Temperature accuracy ±1 °C ±0.5% of reading
Sensor maximum working pressure 1,450 psig (100 barg)
Micro Motion 2400S Compact, Integral-Mount Transmitter
Output variables Mass & volume flow, Net product content / flow, Temperature, Density, Concentration
Local display Standard user interface with 2-line LCD panel
Power Self-switching AC/DC input, automatically recognizes supply voltage (85–265 VAC, 50/60 Hz, 4 watts typical, 7 watts maximum; 18–100 VDC, 4 watts typical, 7 watts maximum)
Input/output signals (analog output option) Channel A: One active 4–20 mA output; Not intrinsically safe
Mounting options Field mount, integral with sensor
Application types Continuous process control, Two-phase flow/entrained gas, Meter verification
Hazardous approvals C1D2, Zone 2

 