Micro Motion H-Series Hygienic Coriolis Meter | DN250-DN350 | 316L Stainless Steel | H400S Sensor with 3500 Transmitter

As a supplier, the Micro Motion H-Series Hygienic Coriolis Meter, consisting of the H400S sensor and 3500 transmitter, delivers exceptional performance, ensuring precise density measurement and rapid product changeovers. Our efficient supply chain guarantees timely delivery and ample inventory to meet customer customization needs. Additionally, the 3500 controller features comprehensive configuration capabilities and a programmable display, significantly reducing labor and maintenance costs for your facility. We also provide extensive technical support and maintenance services, ensuring a seamless experience for our customers and helping drive your business success.

  • Free Selection Free Online Product Selection Service

To pick up today

  • Fast Shipping & Competitive pricing

Our courier will deliver to the specified address

  • warranty Min. order: 1 piece & 2-Year Warranty

DHL courier will deliver to the specified address

Payment Methods:

Description

Specification Details
Micro Motion H400S Hygienic Coriolis Meter 4 Inch (DN100), 316L Stainless Steel, 32 RA Finish
Mass Flow Accuracy (Liquid) Up to ±0.05% of rate
Mass Flow Repeatability (Liquid) Up to ±0.025% of rate
Volume Flow Accuracy (Liquid) Up to ±0.05% of rate
Volume Flow Repeatability (Liquid) Up to ±0.025% of rate
Mass Flow Accuracy (Gas) Up to ±0.35% of rate
Mass Flow Repeatability (Gas) Up to ±0.175% of rate
Density Accuracy (Liquid) Up to ±0.0005 g/cm³ (±0.5 kg/m³)
Temperature Accuracy ±1 °C ±0.5% of reading
Maximum Working Pressure 1,450 psig (100 barg)
Micro Motion 3500 Controller and Transmitter Remote Rack/Panel-Mount
Output Variables Mass & volume flow, net product content/flow, temperature, density, concentration
Local Display Multi-line LCD panel, backlit LCD, 128 × 128 pixel, adjustable contrast
Power Options AC: 85 to 265 VAC, 50/60 Hz, 30 VA; DC: 18 to 30 VDC, 18 watts typical
Input/Output Signals Two active 4–20 mA, three discrete outputs, one 2-wire frequency output, two discrete momentary inputs
Mounting Options Control-room DIN rail or panel-mount
Application Types Batch controller, custody transfer, two-phase flow/entrained gas, meter verification
Hazardous Approvals Suitable for non-hazardous areas only