Micro Motion F-Series Coriolis Meter | DN15 | 316L Stainless Steel | F050A Sensor with 3500 Transmitter (High Temperature)

As a supplier of high-quality flow measurement solutions, we offer the Micro Motion F-Series Coriolis Meter, consisting of the F050A sensor and the 3500 transmitter. This sensor, made from 316L stainless steel, features high-temperature and high-pressure capabilities, ensuring a mass flow accuracy of ±0.20%, suitable for various fluid measurements. The 3500 transmitter provides flexible output options and an intuitive multi-line LCD display, reducing maintenance and operating costs while enhancing production efficiency. Equipped with extensive certifications and real-time process diagnostics, choosing the F-Series products will help you optimize production processes and improve product quality and operational efficiency.

  • Free Selection Free Online Product Selection Service

To pick up today

  • Fast Shipping & Competitive pricing

Our courier will deliver to the specified address

  • warranty Min. order: 1 piece & 2-Year Warranty

DHL courier will deliver to the specified address

Payment Methods:

Description

Micro Motion F050A Coriolis Meter 1/2 Inch (DN15), 316L Stainless Steel, High Temperature
Mass Flow Accuracy (Liquid) ±0.20% of rate (standard), ±0.15% of rate (optional), ±0.10% of rate (optional)
Mass Flow Repeatability (Liquid) ±0.050% of rate
Volume Flow Accuracy (Liquid) ±0.20% of rate (standard), ±0.15% of rate (optional), ±0.10% of rate (optional)
Volume Flow Repeatability (Liquid) ±0.050% of rate
Mass Flow Accuracy (Gas) ±0.5% of rate
Mass Flow Repeatability (Gas) ±0.25% of rate
Density Accuracy (Liquid) ±0.002 g/cm³ (2.0 kg/m³) (standard), ±0.001 g/cm³ (1.0 kg/m³) (optional)
Temperature Accuracy ±1 °C ±0.5% of reading
Max Working Pressure 1,450 psig (100 barg)
Approvals and Certifications UL, CSA, IECEx, NEPSI, ATEX, Ingress Protection, EMC effects
Micro Motion 3500 Controller And Transmitter Remote Rack/Panel-Mount
Output Variables Mass & volume flow, Net product content/flow, Temperature, Density, Concentration
Local Display Multi-line LCD panel, Backlit, 128 × 128 pixel
Power (AC Option) 85 to 265 VAC, 50/60 Hz, 30 VA
Power (DC Option) 18 to 30 VDC, 18 watts typical, 25 watts maximum
Input/Output Signals Two active 4–20 mA, Three discrete outputs, One 2-wire frequency output
Mounting Options Control-room DIN rail or panel-mount
Application Types Batch controller, Custody transfer, Two-phase flow/entrained gas, Meter verification
Hazardous Approvals Suitable for non-hazardous areas only