Specifications |
Description |
Rosemount 8705010 Flanged Magnetic Flow Meter Sensor, 1 Inch (DN25) |
|
Accuracy |
Up to 0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.25% over 40:1 flow turndown |
Line Sizes |
½-36 inch (15-900 mm) |
Liner Materials |
PTFE, ETFE, PFA, Polyurethane, Neoprene, Linatex Natural Rubber, Consult factory for additional material options |
Electrode Materials |
ASME B16.5 Class 150-2500
DIN PN 10-40
AS 2129 Table D and E
AWWA C207 Table 3 Class D (30-36 inch only) |
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters |
|
Sensor compatibility |
Compatible with Rosemount 8705, 8711, and 8721 sensors. Compatible with AC and DC powered sensors of other manufacturers. |
Transmitter coil drive current |
500mA |
Flow rate range |
Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s). |
Conductivity limits |
Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater. |
Power supply |
90 – 250VAC, 50/60Hz or 12 – 42VDC |
Line power fuses (90-250VAC systems) |
1A, 250V, I2t, 1.5 A2s Rating, Fast Acting
Bussman AGC-1, Littlefuse 31201.5HXP |
Line power fuses (12-42VDC systems) |
3 Amp, 250V, I2t, 14 A2s Rating, Fast Acting
Bel Fuse 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135 |
Line power fuses limits |
15W maximum – DC
40VA maximum – AC |
Switch-on current |
AC: Maximum 35.7A (< 5ms) at 250VAC
DC: Maximum 42A (< 5ms) at 42VDC |