214CRWSMA1S3M0125SLI7X8Q4M2XAXW | Rosemount 214C RTD Temperature Sensor

Part Number: 214CRWSMA1S3M0125SLI7X8Q4M2XAXW

  • Free Selection Free Online Product Selection Service

To pick up today

  • Fast Shipping & Competitive pricing

Our courier will deliver to the specified address

  • warranty Min. order: 1 piece & 2-Year Warranty

DHL courier will deliver to the specified address

Payment Methods:

Description

Part Number: 214CRWSMA1S3M0125SLI7X8Q4M2XAXW

Model: 214C RTD Temperature Sensor
Manufacturer: Rosemount™
Specifications
  • Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008
  • Lead Wires: 24 AWG wire, FEP insulated; color coded per IEC 60751
  • Time Constant / Response: 10.8 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 60751:2008
  • Stability: ±0.15 °C (0.059 ) maximum ice-point resistance shift following 1,000 hours at maximum specified temperature when measured per methods defined in IEC 60751:2008
  • Insulation Resistance: 1000 MO minimum insulation resistance when measured at 500 VDC at room temperature
  • Calibration Options: IEC 751 Class A or B; Single point calibration; Calibration schedule or customer-specified calibration range, both with Callendar-Van Dusen constants
Features
  • Single or dual element Pt-100 RTD with thin-film or wire-wound designs meets various application requirements
  • Thin film sensor engineered to withstand high vibration industrial applications
  • Wire-wound design for applications requiring high accuracy, dual-elements and/or are subjected to high temperatures
  • Covers a wide range of temperatures from –321 to 1112°F (–196 to 600°C) for application flexibility
  • Callendar-Van Dusen constants allow for transmitter-sensor matching and offer the highest level of accuracy
  • Optional Class A accuracy ensures critical temperature measurement points meet tolerance and accuracy standards
  • Adaptable design with a variety of enclosure and connection head options meet varying application demands
  • Includes spring-loaded or compact spring-loaded mounting styles for adaptability
  • North American approvals meet hazardous location requirements

Customer Reviews