YTA610-JA1A2DN/A/FU1 | Yokogawa YTA610 | Yokogawa Temperature Transmitter

Part Number: YTA610-JA1A2DN/A/FU1

  • Free Selection Free Online Product Selection Service

To pick up today

  • Fast Shipping & Competitive pricing

Our courier will deliver to the specified address

  • warranty Min. order: 1 piece & 2-Year Warranty

DHL courier will deliver to the specified address

Payment Methods:

Description

Part Number: YTA610-JA1A2DN/A/FU1

Model and Suffix Codes
  • Model: YTA610 – Temperature Transmitter
  • Output signal: -J – 4 to 20 mA DC with DC digital communication HART 7 protocol
  • A: Always A
  • Sensor input: 1 – Single
  • Housing code: A – Aluminium
  • Electrical code: 2 – 1/2 NPT female
  • Integral indicator: D – Digital indicator with Local Operating Switch
  • Mounting bracket: N – None
  • Option Codes:
    A: Lightning protector
    Allowable current: Max 6000A(8x20us), repeating 1000A(8x20us), 100 times

    FU1:
    4-20mA:
    [Instrinsically safe approval/non-incendive approval]
      Applicable standard: Class 3600:2011, Class 3610:2015, Class 3611:2004, Class 3810:2005,
    ANSI/ISA-60079-0:2013, ANSI/ISA-60079-11:2014, NEMA 250:2003, ANSI/IEC 60529:2004 (R2011)
      Intrinsically safe for
        Class I, II, III Division 1, Groups A, B, C, D, E, F, G, T5…T4
        Class I Zone 0 AEx ia IIC T5…T4
      Non-incendive for
        Class I, II, Division 2, Groups A, B, C, D, F, G, T5…T4
        Class III, Division 1 T5…T4
        Class I Zone Group IIC T5…T4
      Ambient Temperature: -40 to 70?C for T4, -40 to 50?C for T5
      Enclosure Type 4X, IP66/IP67 in accordance with only IEC 60529
      Entity Parameters:
      Intrinsically safe for
        Supply/Output circuit: Ui=30V, li=200mA, Pi=1.0W, Ci-22nF, Li=0mH
        Sensor circuit: Uo=6V, Io=90mA, Po=135mW, Co=10?F, Lo=3.9mH
      Non-incendive for
        Supply/Output circuit: Ui=30V, Ci=22nF, Li=0mH
        Sensor circuit: Uo=6V, Io=90mA, Po=135mW, Co=10?F, Lo=3.9mH
      Dielectric strength: 500 V a.c.r.m.s., 1 min
      [+, -, C, 1, 2, 3, 4, 5] to Earth terminal
      [+, -, C] to [1, 2, 3, 4, 5]
    [Explosionproof approval]
      Applicable standard: Class 3600, Class 3615, Class 3810, ANSI/NEMA 250
      Class I, Division 1, Groups A, B, C, D.;
      Class II/III, Division 1, Groups E, F and G.
      ‘FACTORY SEALD, CONDUIT SEAL NOT REQUIRED.’
      Enclosure Ratings: TYPE 4X
      Temperature Class: T6
      Ambient Temperature: -40 to 60?C (-40 to 140?F)
      Electrical Connection: 1/2NPT female?

     

NOTE:
  1. Applicable for Electrical Connection Code 2.
  • Estimated Lead Time: 8 – 10 Weeks
  • Shipping Weight: 4 Kg

Customer Reviews