YTA610-JA1A4DD/A/SU2/C2/P2 | Yokogawa YTA610 | Yokogawa Temperature Transmitter

Part Number: YTA610-JA1A4DD/A/SU2/C2/P2

  • Free Selection Free Online Product Selection Service

To pick up today

  • Fast Shipping & Competitive pricing

Our courier will deliver to the specified address

  • warranty Min. order: 1 piece & 2-Year Warranty

DHL courier will deliver to the specified address

Payment Methods:

Description

Part Number: YTA610-JA1A4DD/A/SU2/C2/P2

Model: YTA610 Temperature Transmitter
Manufacturer: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Ordering Information

Model YTA610 Temperature Transmitter
Output Signal -J 4 to 20 mA DC with digital communication HART protocol
A Always A (Global)
Sensor input 1 Single
Housing code A Aluminum
Electrical connection 4 M20 female
Integral indicator D Digital indicator with Local Operating Switch
Mounting bracket D SUS304 stainless steel 2-inch vertical pipe mounting bracket
Lighting protector¹ /A Allowable current: Max. 6000A(8×20µs), repeating 1000A(8×20µs), 100 times
IECEx /SU2 4-20mA:
[Intrinsically safe ia, ic pproval]
Applicable Standard: IEC 60079-0, IEC 60079-11
Certificate No. IECEx FMG 16.0014X
Ex ia IIC T5…T4 Ga
Ex ic IIC T5…T4 Gc
Ex ia [ia Da] IIIC T135°C Db
Ambient Temperature:
–40 to +70°C for T4 (Ex ia), –40 to +50°C for T5 (Ex ia), –30 to +70°C for IIIC (Ex ia),

–30 to +70°C for T4 (Ex ic), –30 to +50°C for T5 (Ex ic)
Enclosure: IP66/IP67
Over voltage category: I
Electrical parameters (Ex ia)
Supply/Output circuit: Terminal: +, –
Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10µF, Lo=3.9mH
Electrical parameters (Ex ic)
Supply/Output circuit: Terminal: +, –
Ui=30V, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10µF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Flameproof and Dust Ignition Proof Approval]
Applicable standard: IEC 60079-0, IEC 60079-1, IEC 60079-31
Certificate: IECEx KEM 07.0044X
Ex db IIC T6/T5 Gb, Ex tb IIIC T70°C/T90°C Db
Ambient Temperature for Gas Atmospheres: –40 to 75°C (–40 to 167°F) for T6,
–40 to 80°C (–40 to 176°F) for T5

Ambient Temperature for Dust Atmospheres: –30 to 65°C (–22 to 149°F) for T70°C,
–30 to 80°C (–22 to 176°F) for T90°C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female²

NAMUR NE43 compliant³ /C2 Output signal limits:
3.8 mA to 20.5 mA
Failure alarm down-scale: output status at CPU failure and
hardware error is –5%, 3.2 mA or less.
Sensor burnout is also set to Low: –2.5%, 3.6 mA DC.
Painting4,5 /P2 Color and coating change
Amplifier cover only6

Color: Munsell code 7.5BG4/1.5, Jade green
Coating: High anti-corrosion coating

  1. Lightning protector (surge absorber) can be remove from, or added to the equipment.
  2. Applicable for Electrical Connection Code 2 and 4.
  3. Not applicable for Fieldbus type.
  4. Not applicable for Stainless housing.
  5. The combination of X2 and P? is not possible.
  6. Except for Amplifier and terminal cover, color and coating are general specification.
  • Estimated Lead Time: 25 Weeks
  • Shipping Weight: 5 Kg