YTA710-FA2C4DK/SU25 | Yokogawa YTA710 | Yokogawa Temperature Transmitter

Part Number: YTA710-FA2C4DK/SU25

  • Free Selection Free Online Product Selection Service

To pick up today

  • Fast Shipping & Competitive pricing

Our courier will deliver to the specified address

  • warranty Min. order: 1 piece & 2-Year Warranty

DHL courier will deliver to the specified address

Payment Methods:

Description

Part Number: YTA710-FA2C4DK/SU25

Model: YTA710 Temperature Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months
Overview
The YTA710 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20mA DC analog signal or Fieldbus digital signal. HART 7 Protocol, BRAIN Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.
By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.
YTA710 features include:
  • Dual-compartment field-mount housing
  • Choice of HART 7, BRAIN Protocol or FOUNDATION Fieldbus ITK 6 Protocol
  • Local Parameter Setting function (Indicator model)
  • Advanced diagnosis

Ordering Information

Model YTA710 Temperature Transmitter
Output signal -F Digital communication (FOUNDATION Fieldbus protocol)
A Always A (Global)
Sensor input 2 Double
Housing code C Stainless
Electrical connection 4 M20 female
Integral indicator D Digital indicator with Local Operating Switch
Mounting bracket K 316 SST or ASTM316L stainless steel 2-inch vertical pipe mounting bracket
IECEx /SU25 Fieldbus:
[Intrinsically safe ia approval]
Applicable Standard: IEC 60079-0, IEC 60079-11
Certificate No. IECEx FMG 16.0014X
Ex ia IIC T4 Ga
Ex ic IIC T4 Gc
Ex ia [ia Da] IIIC T135°C Db
Ambient Temperature: –55 to +60°C for T4 (Ex ia)
Ambient Temperature: –30 to +60°C for IIIC (Ex ia)
–30 to +70°C (Ex ic)
Enclosure: IP66/IP67
Overvoltage category: I
Electrical parameters (Ex ia)
Supply/Output circuit: Terminals: +, –
FISCO field device or
Ui=30V, Ii=300mA, Pi=1.2W, Ci=2.2nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10µF, Lo=3.9mH
Electrical parameters (Ex ic)
Supply/Output circuit: Terminals: +, –
FISCO field device or
Ui=32V, Ci=2.2nF, Li=0mH
Sensor circuit:Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10µF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Flameproof and Dust Ignition Proof Approval]
Same as SF2
  • Estimated Lead Time: 3 – 4 Months
  • Shipping Weight: 8 Kg