Model |
266DSH |
Differential Pressure Transmitter – BASE ACCURACY 0.06 % |
SENSOR – Span limits |
F |
0.4 and 40 kPa 4 and 400 mbar 1.6 and 160 inH2O |
Application |
S |
Differential measurement at standard static pressure |
Diaphragm material / Fill fluid (wetted parts) |
S |
AISI 316 L ss Silicone oil (Note 1) NACE |
Process flanges/adapters material and connection (wetted parts) |
B |
AISI 316 L ss (Horizontal connection) 1/2 in. – 14 NPT-f through adapter NACE |
Bolts/Gasket (wetted parts) |
1 |
For standard static, high static
and gauge versions AISI 316 ss Viton® (Notes 2, 3, 4, 5) NACE (non exposed) |
Housing material and electrical connection |
S |
AISI 316 L ss ( barrel version) (I2 or I3 required) 1/2 in. – 14 NPT (Notes 6) |
Output/Additional options |
1 |
HART and 4 to 20 mA – Advanced functionality (includes option R1) |
Drain/vent valve (material and position) (wetted parts) |
V1 |
AISI 316 L ss on process axis (Notes 3, 7) NACE |
Hazardous area certifications (see relevant paragraph for complete detailed markings) |
EA |
FM Approvals (USA and Canada) Intrinsically Safe |
Integral LCD |
L1 |
Digital LCD integral display with integrated keypad (Notes 8) |
Mounting bracket (shape and material) |
B2 |
For pipe/wall mounting – AISI 316 L ss (Notes 4) |
Additional tag plate |
I2 |
Tag and certification stainless steel plates (laser printed) |
Certificates (multiple selection allowed) |
C6
|
Certificate of compliance with the order EN 10204–2.1 of instrument design |
Material traceability |
H3 |
Inspection certificate EN 10204–3.1 of process wetted parts (not for gaskets) |