Micro Motion F-Series Coriolis Meter | DN15 | 316L Stainless Steel | F050P Sensor with 2500 Transmitter (High Pressure)

As a supplier, we offer the Micro Motion F-Series Coriolis Meter, which includes the F050P sensor and 2500 transmitter. This high-performance combination, made from 316L stainless steel, provides exceptional accuracy in mass and volume flow measurements under high pressure, suitable for various industrial applications. Our products come with multiple international certifications, ensuring reliability in diverse environments. With a strong supply chain, we maintain ample stock to quickly respond to customer needs, alongside comprehensive technical support and excellent after-sales service to help clients enhance production efficiency. By choosing our Micro Motion F-Series meter, you gain high-precision measurement and an outstanding service experience.

  • Free Selection Free Online Product Selection Service

To pick up today

  • Fast Shipping & Competitive pricing

Our courier will deliver to the specified address

  • warranty Min. order: 1 piece & 2-Year Warranty

DHL courier will deliver to the specified address

Payment Methods:

Description

Micro Motion F050P Coriolis Meter 1/2 Inch (DN15), 316L Stainless Steel, High Pressure
Mass Flow Accuracy (Liquid) ±0.20% of rate (standard), ±0.15% of rate (optional), ±0.10% of rate (optional)
Mass Flow Repeatability (Liquid) ±0.050% of rate
Volume Flow Accuracy (Liquid) ±0.20% of rate (standard), ±0.15% of rate (optional), ±0.10% of rate (optional)
Volume Flow Repeatability (Liquid) ±0.050% of rate
Mass Flow Accuracy (Gas) ±0.5% of rate
Mass Flow Repeatability (Gas) ±0.25% of rate
Density Accuracy (Liquid) ±0.002 g/cm³ (2.0 kg/m³) (standard), ±0.001 g/cm³ (1.0 kg/m³) (optional)
Temperature Accuracy ±1 °C ±0.5% of reading
Sensor Maximum Working Pressure 5,000 psig (344 barg)
Meter Approvals, Calibrations, and Certifications • UL
• CSA
• IECEx
• NEPSI
• ATEX
• Ingress Protection
• EMC effects
Micro Motion 2500 Compact Control Room Multivariable Flow and Density Transmitter
Output Variables • Mass & Volume Flow
• Net Product Content / Flow
• Temperature
• Density
• Concentration
Local Display None
Power • Minimum 19.2 to 28.8 VDC
• 6.3 watts
• Meets Installation (Overvoltage) Category II, Pollution Degree 2 requirements
Input/Output Signals • One active 4–20 mA output
• One active frequency output
HART Bell 202 signal is superimposed on the primary milliamp output
Mounting Options Mounted on 35 mm rail (rail must be grounded)
Application Types • Continuous Process Control
• Two-Phase Flow/Entrained Gas
• Meter Verification
Hazardous Approvals Suitable for non-hazardous environments only

Customer Reviews