Rosemount 214C RTD Temperature Sensor and 644 Transmitter and 114C Thermowell

As a supplier focused on providing reliable and efficient temperature measurement solutions, we offer the Rosemount 214C RTD Temperature Sensor, 644 Temperature Transmitter, and 114C Thermowell as a powerful combination for demanding industrial applications. The 214C sensor delivers accurate temperature readings with high stability and insulation resistance, while the 644 transmitter ensures seamless data transmission with multiple protocol options and advanced diagnostics for continuous performance monitoring. The 114C thermowell adds an extra layer of protection, offering customizable designs and rigorous testing to ensure durability in harsh environments. Together, this integrated solution guarantees precise measurement, enhanced safety, and long-term reliability for critical processes. We also provide fast delivery and technical support to meet your operational needs.

  • Free Selection Free Online Product Selection Service

To pick up today

  • Fast Shipping & Competitive pricing

Our courier will deliver to the specified address

  • warranty Min. order: 1 piece & 2-Year Warranty

DHL courier will deliver to the specified address

Payment Methods:

Description

Specifications

Rosemount 214C RTD Temperature Sensor Rosemount 644 Temperature Transmitter Rosemount 114C Thermowell
Temperature Range: 0.05 °C (0.020 Ω) maximum ice-point resistance shift after 1g vibration, 20-500 Hz, 150 hours (IEC 60751:2008) Input: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms) Thermowell Calculations: Wake frequency calculation (WFC) performed by certified engineers, order R21 for official report
Lead Wires: 24 AWG wire, FEP insulated; color coded per IEC 60751 Output Signal: 4-20 mA /HART™ protocol, FOUNDATION™ fieldbus protocol, PROFIBUS™ PA protocol Design Modifiers: Root, bore, and tip diameters can be customized for any application
Time Constant / Response: 10.8 seconds max to reach 50% sensor response in flowing water (IEC 60751:2008) Housing: Field mount, DIN A head mount or rail mount Certifications/Approvals: Material certification, NACE, CRN (see full specs for complete list of certifications)
Stability: ±0.15 °C (0.059 Ω) max ice-point resistance shift after 1,000 hours at max temperature (IEC 60751:2008) Display/Interface: LCD Display, LCD Display with Local Operator Interface (LOI), or LED Product Tests: External pressure test, internal pressure test, dye penetration, X-ray, PMI (see full specs for complete list)
Insulation Resistance: 1000 MΩ min insulation resistance at 500 VDC at room temperature Diagnostics: Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max tracking
Calibration Options: IEC 751 Class A or B, single point calibration, customer-specified calibration range with Callendar-Van Dusen constants Calibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants), 5-point calibration
Certifications/Approvals: SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type (see full specs for complete list of certifications)

Customer Reviews