Rosemount 8721015 Hygienic Magnetic Flow Meter Sensor, 1.5 Inch (DN40)
Accuracy Up to 0.25% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.5% over 40:1 flow turndown
Line Sizes ½-4 inch (15-100 mm)
Liner Materials PFA
Electrode Materials 316L Stainless Steel, Nickel Alloy, Platinum
Process Connections Tri-Clamp® Sanitary Coupling IDF Sanitary Coupling (screw type) Weld Nipple DIN 11851 (Imperial and Metric) DIN 11864 (-1 and -2 Form A) SMS 1145 DEN US 50 Weld Nipple
Product Certifications 3-A, EHEDG Type EL, PMO (M-b-350)
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
Sensor compatibility Compatible with Rosemount 8705, 8711, and 8721 sensors. Compatible with AC and DC powered sensors of other manufacturers.
Transmitter coil drive current 500mA
Flow rate range Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s).
Conductivity limits Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater.
Power supply
  • 90 – 250VAC, 50/60Hz or 12 – 42VDC
  • Line power fuses:
    • 90-250VAC systems:
      • 1A, 250V, I2t, 1.5 A2s Rating, Fast Acting. Bussman AGC-1, Littlefuse 31201.5HXP
    • 12-42VDC systems:
      • 3 Amp, 250V, I2t, 14 A2s Rating, Fast Acting. Bel Fuse 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135
  • Line power fuses: 15W maximum – DC, 40VA maximum – AC
  • Switch-on current:
    • AC: Maximum 35.7A (< 5ms) at 250VAC
    • DC: Maximum 42A (< 5ms) at 42VDC