Rosemount 8721040 Hygienic Magnetic Flow Meter Sensor
Accuracy
Up to 0.25% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.5% over 40:1 flow turndown
Line Sizes ½-4 inch (15-100 mm)
Liner Materials PFA
Electrode Materials 316L Stainless Steel, Nickel Alloy, Platinum
Process Connections Tri-Clamp® Sanitary Coupling
IDF Sanitary Coupling (screw type)
Weld Nipple DIN 11851 (Imperial and Metric)
DIN 11864 (-1 and -2 Form A)
SMS 1145 DEN US 50 Weld Nipple
Product Certifications 3-A, EHEDG Type EL, PMO (M-b-350)
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
Sensor compatibility
Compatible with Rosemount 8705, 8711, and 8721 sensors. Compatible with AC and DC powered sensors of other manufacturers.
Transmitter coil drive current 500mA
Flow rate range Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s).
Conductivity limits Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater.
Power supply 90 – 250VAC, 50/60Hz or 12 – 42VDC
Line power fuses 90-250VAC systems:
1A, 250V, I2t, 1.5 A2s Rating, Fast Acting
Bussman AGC-1, Littlefuse 31201.5HXP
12-42VDC systems:
3 Amp, 250V, I2t, 14 A2s Rating, Fast Acting
Bel Fuse 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135
Line power fuses 15W maximum – DC
40VA maximum – AC
Switch-on current AC: Maximum 35.7A (< 5ms) at 250VAC
DC: Maximum 42A (< 5ms) at 42VDC