Rosemount MS Magnetic Sensor MS080 for Slurry Applications, 8 inch (DN200)
Reference Accuracy ±0.25% with optional ±0.15% high accuracy
Line Size 3” (80mm) to 36” (900mm)
Liner Material Options PTFE, PFA+, Polyurethane, Neoprene, Linatex Natural Rubber, Adiprene
Electrode Options
  • Material: 316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium
  • Type: Standard, Bullet, Flat
  • Optional 3rd electrode for grounding
Flange Options
  • Connections: Slip-on, weld-neck, grooved coupling
  • Ratings: ASME Class 150 – 2500, EN-1092 PN10 – PN40, AS2129 Table D and E, JIS B2220 10K – 40K, AS4087 PN16 – PN35
  • Materials: Carbon Steel, 304/304L SST, 316/316L SST
  • Additional flange ratings and materials may be available upon request
Approvals
  • Ordinary Locations
  • ATEX Non-Sparking; Dust
  • Class I Div 2; Dust
  • Class I Zone 2; Dust
  • IECEx Non-Sparking; Dust
  • ATEX increased safety; Dust
  • Class I Zone1; Dust
  • IECEx Increase Safety; Dust
  • Higher level approvals include Intrinsically Safe Electrodes
Enclosure Type Type 4X
IP66, IP67, IP68, IP73
Compatibility 8782 Slurry Transmitter for optimum performance in high noise applications
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
Sensor compatibility Compatible with Rosemount 8705, 8711, and 8721 sensors. Compatible with AC and DC powered sensors of other manufacturers.
Transmitter coil drive current 500mA
Flow rate range Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s).
Conductivity limits Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater.
Power supply
  • 90 – 250VAC, 50/60Hz or 12 – 42VDC
  • Line power fuses:
    • 90-250VAC systems:
      • 1A, 250V, I2t, 1.5 A2s Rating, Fast Acting. Bussman AGC-1, Littlefuse 312