STF724-B1HS1A-H1F-0-EH0-13S-A-00A0-00-0000 | Honeywell STF724 | HoneyWell Level Transmitter

Part Number: STF724-B1HS1A-H1F-0-EH0-13S-A-00A0-00-0000

  • Free Selection Free Online Product Selection Service

To pick up today

  • Fast Shipping & Competitive pricing

Our courier will deliver to the specified address

  • warranty Min. order: 1 piece & 2-Year Warranty

DHL courier will deliver to the specified address

Payment Methods:

Description

Part Number: STF724-B1HS1A-H1F-0-EH0-13S-A-00A0-00-0000

Model: STF72F SmartLine Flange-Mounted Level Transmitter
Manufacturer: Honeywell
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Ordering Information

Model STF724 Model STF700 Flange Mounted Liquid Level Transmitter
Process Wetted Heads & Diaphragm Materials B Design: Flush
Ref. Head: Carbon steel(1)
Vent DrainValve on Ref. Head(2): 316 SS
Barrier Diaphrm. (wetted): Hast C(3)
Diaphrm. Plate (wetted): Hast C(3)
Extension (wetted): N/A
Fill Fluid (Meter Body & Flange) 1 Silicone Oil 200
Process Connection H Reference Head: 1/2 NPT Adapter – material matches head material
and head bolt material(4)
Flange: High Pressure Side
Bolts for Process Heads S 316 SS Bolts
Vent/Drain Type/Location 1 Ref. Head Type: Single Ended
Vent Type: None
Location: None
Vent Material: None
Gasket Material A Teflon® or PTFE (Glass Filled)
Flange(ANSI Flanges have125-500 AARH Surface Finish) H 3′ ANSI Class 150
Flange Material: 316 SS
(non-wetted)
Threaded Nut Ring Material: 304 SS
(non-wetted)
Gasket Ring (wetted) 1 Flush Design
316L SS
Extension (wetted) F Flush
Approvals 0 No Approvals Required
Electronic Housing Material & Connection Type E Material: 316 Stainless Steel (Grade CF8M)
Connection: 1/2 NPT
Lighting Protection: None
Output/Protocol H Analog Output: 4-20mA dc
Digital Protocol: HART Protocol
Customer Interface Selections 0 Indicator: None
Ext Zero, Span & Config Buttons: None
Languages: None
Application Software 1 Standard Diagnostics
Output Limit, Failsafe & Write Protect Settings 3 Write Protect: Enabled
Fail Mode: High> 21.0mAdc
High & Low Output Limits(5): Honeywell Std (3.8 – 20.8 mAdc)
General Configuration S Factory Standard
Accuracy and Calibration A Accuracy: Standard
Calibrated Range: Standard
Calibration Qty: Single Calibration
Mounting Bracket 0 None (not required with flange mount unit)
Customer Tag 0 No customer tag
Unassembled Conduit Plugs & Adapters A0 No Conduit Plugs or Adapters Required
Certifications & Warranty 00 None – No additional options
Factory 0000 Factory Identification
  1. Carbon Steel heads are zinc-plated and not recommended for w ater service due to hydrogen migration. For that service, use
    the 316 stainless steel Wetted Reference Head.
  2. Vent/Drains are Teflon or PTFE coated for lubricity.
  3. Hastelloy® C-276 or UNS N10276
  4. Except Carbon Steel Heads shall use 316SS Vent/Drain, Plugs & Adapters when required
  5. NAMUR Output Limits 3.8 – 20.5mAdc can be configured by the customer or select custom configuration Table Vc
  • Estimated Lead Time: 12 – 18 Weeks