NEPSI(3) |
/NS2 |
4-20mA:
[Intrinsically safe approval ]
Applicable Standard: GB3836.1-2010, GB3836.4-2010, GB3836.20-2010, GB3836.19-2010, GB12476.1-2013, GB12476.4-2010
Certificate No.: GYJ21.1262X
Ex ia IIC T4/T5 Ga
Ex ic IIC T4/T5 Gc
Ex iaD [iaD 20] 21 IP6X T135°C
Ambient Temperature:
–40 to 70°C for T4, –40 to 50°C for T5(Ex ia)
–30 to 70°C(Ex iaD)
–30 to 70°C for T4, –30 to 50°C for T5(Ex ic)
Enclosure: IP66/IP67
Overvoltage category: I
Electrical parameters (Ex ia):
Supply/Output circuit: Terminals: +, –
Ui = 30 V, Ii = 200 mA, Pi = 1.0 W, Ci = 22 nF, Li = 0 mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo = 6 V, Io = 90 mA, Po = 135 mW, Co = 10 µF, Lo = 3.9 mH
Electrial parameters (Ex ic):
Supply/Output circuit: Terminals: +, –
Ui = 30 V, Ci = 22 nF, Li = 0 mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo = 6 V, Io = 90 mA, Po = 135 mW, Co = 10 µF, Lo = 3.9 mH
Dielectric strength: 500 V a.c.r.m.s., 1 min (Without /A) |