ATEX |
/KU2 |
4-20mA:
[Intrinsically safe approval]
Applicable Standard: EN 60079-0: 2012+A11:2013, EN 60079-11: 2012
Certificate No. FM16ATEX0019X
II 1 G Ex ia IIC T5…T4 Ga
II 2 (1) D Ex ia [ia Da] IIIC T135°C Db
Ambient Temperature: –40 to +70°C for T4, –40 to +50°C for T5, –30 to +70°C for IIIC
Enclosure: IP66/IP67
Electrical parameters:
Supply/Output circuit: Terminals: +, –
Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10µF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Intrinsically safe ic]
Applicable Standard: EN IEC 60079-0, EN 60079-11
Certificate: Not Applicable as per Annex VIII to ATEX 2014/34/EU
II 3 G Ex ic IIC T5…T4 Gc
Ambient Temperature: –30 to +70°C for T4, –30 to +50°C for T5
Enclosure: IP66/IP67
Overvoltage category: I
Electrical parameters:
Supply/Output circuit: Terminals: +, –
Ui=30V, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10µF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Flameproof and Dust Ignition Proof Approval]
Applicable Standard: EN IEC 60079-0, EN 60079-1, EN 60079-31
Certificate: KEMA 07ATEX0130X
II 2 G Ex db IIC T6/T5 Gb, II 2 D Ex tb IIIC T70°C/T90°C Db
Ambient Temperature for Gas Atmospheres: –40 to 75°C for T6, –40 to 80°C for T5
Ambient Temperature for Dust Atmospheres: –30 to 65°C for T70°C, –30 to 80°C for T90°C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female(2) |